Renault Zoe Phase 2

These can help in the vehicle starting phase, or give information about a selection or a driving status.

Examples of information messages are given in the following pages.

Examples of messages

Interpreting the display selected

“Disconnect cable to start”

Indicates that the charging cord is still plugged into the vehicle.

“Parking Brake ON”

Indicates that the parking brake has been applied.

“Steering not locked”

Indicates that the steering column has not been locked.

“Earth connection not compliant”

Indicates a fault in the earthing of the charging terminal ELECTRIC VEHICLE: charging: have the electrical system checked by a qualified professional.

“Check connections”

Unplug, then plug in the vehicle.

If the message still shows, this may be caused by the external charging conditions or by the home installation.

“Check charging station”

Indicates a possible electrical fault or a defective charging cable: change the charging terminal or location or have the cable checked.

“Power cut while charging”

Indicates an electrical fault while charging. Restart charging.

If this does not work, have the electrical installation checked.

“Charging refused no contract”

Charging prohibited by your battery rental organisation. Rectify the situation.